We live motion
   
Magnetic incremental measurement HIWIN MAGIC inquiry

Positioning measurement system with separate encoder (not possible integrated in linear guideway)

  • Zero contact measurement with analog or digital output
  • Digital resolution of up to 0.5 μm
  • Encoder and housing are resistant to dust, humidity, oil and chips
  • Encoder with metal housing and IP67 protection mode
  • Simple assembly
  • Signal output in real time
  • Special housing for EMC optimization

 

 



Basic parameters encoder head measuring MAGIC

Part number Code For guideway Output signal Resolution Repeatability bidirectional Absolute accuracy Operating voltage Max. measurement speed Cable legth [m]
8-08-0120 PM-B-05-0A-T-10 - sin/cos 1Vpp ∞, period 1mm ± 0,003 mm ± 20µm/m 5V ± 5% 10m/s 5
8-08-0502 PM-B-01-0A-T-10 - sin/cos 1Vpp ∞, period 1mm ± 0,003 mm ± 20µm/m 5V ± 5% 10m/s 1
8-08-0122 PM-B-05-0D-T-10 - TTL dle RS 422 1µm ± 0,002 mm ± 20µm/m 5V ± 5% 5m/s 5
8-08-0503 PM-B-01-0D-T-10 - TTL dle RS 422 1µm ± 0,002 mm ± 20µm/m 5V ± 5% 5m/s 1
* - It is not designed for using in drag chain. For this purpose, we recommend that the encoder with connector and that the signal be carried by a special cable.

Basic parameters positioning scale with protecting

Part number Code Max. length [m] Pole pitch [mm] Accuracy class Weight [g/m]
8-08-0028-xxxx* PS-B-0000 24 1 ± 20µm/m 70

Basic parameters display PMED for measuring MAGIC a MAGIC-PG

Part number Code Resolution Input signal Operating voltage Relay contact rating 3D (STP)
8-08-0250 PMED-H2-1-00-1 1µm, 2µm, 5µm, 10µm analog: sin/cos 1Vpp, digital: 5V RS422/TTL 5V ±5%/1A DC 24V/2A