Positioning measurement system with separate encoder (not possible integrated in linear guideway)
Part number | Code | For guideway | Output signal | Resolution | Repeatability bidirectional | Absolute accuracy | Operating voltage | Max. measurement speed | Cable legth [m] |
---|---|---|---|---|---|---|---|---|---|
8-08-0120 | PM-B-05-0A-T-10 | - | sin/cos 1Vpp | ∞, period 1mm | ± 0,003 mm | ± 20µm/m | 5V ± 5% | 10m/s | 5 |
8-08-0502 | PM-B-01-0A-T-10 | - | sin/cos 1Vpp | ∞, period 1mm | ± 0,003 mm | ± 20µm/m | 5V ± 5% | 10m/s | 1 |
8-08-0122 | PM-B-05-0D-T-10 | - | TTL dle RS 422 | 1µm | ± 0,002 mm | ± 20µm/m | 5V ± 5% | 5m/s | 5 |
8-08-0503 | PM-B-01-0D-T-10 | - | TTL dle RS 422 | 1µm | ± 0,002 mm | ± 20µm/m | 5V ± 5% | 5m/s | 1 |
Part number | Code | Max. length [m] | Pole pitch [mm] | Accuracy class | Weight [g/m] | 3D (STP) |
---|---|---|---|---|---|---|
8-08-0028-xxxx* | PS-B-0000 | 24 | 1 | ± 20µm/m | 70 | STEP |
Part number | Code | Resolution | Input signal | Operating voltage | Relay contact rating | 3D (STP) |
---|---|---|---|---|---|---|
8-08-0250 | PMED-H2-1-00-1 | 1µm, 2µm, 5µm, 10µm | analog: sin/cos 1Vpp, digital: 5V RS422/TTL | 5V ±5%/1A | DC 24V/2A | STEP |