TECHNICAL DATA |
|
function | piston pump |
lubricant volume | 125 cm3 in cartridge |
cartridge refillable | no |
volume per stroke | 0,15 cm3 |
number of strokes per cartridge 125 cm3 | ca. 780 |
operating pressure | 35 bar |
control | time-controlled integrated |
lubricant | grease up to NLGI class 2, solid particless possible |
operating temperature | - 10o C … + 60o C |
operating voltage | 4.5V (battery) |
connector | M12x1; 4-pole |
mounting position | vertical, cartridge up |
pressure monitoring | integrated, electronic |
level monitoring | integrated, electronic |
protection class | IP54 |
number of outlets | 1 |
lubrication points | max. 4 |
outlet thread | G 1/4" (o); M6 (i) |
tube length | max. 2m in front of the distributor |
max. 6m behind of the distributor | |
max. 10m without distributor | |
ORDER CODES |
|
FlexxPump 125 DLS | 135-125-000 |
Cartridge for FP125; 125 cm³; grease F03 | 000-103-101 |
Cable M12x1; straight; 4-pole; open end; 5m | 134-002-003 |
Cable M12x1; straight; 4-pole; open end; 10m | 134-002-007 |
Tube 6x4; filled with grease F03 | 134-003-003 |
Batterypack 4,5V; Alkaline; for FlexxPump 125 B | 134-002-025 |