We live motion
   
FlexxPump 250 DLS inquiry

Controlled minimum quantity lubrication for grease.
Pulse controlled by PLC.

TECHNICAL DATA

function piston pump
lubricant volume 250 cm3 in cartridge
cartridge refillable no
volume per stroke 0,15 cm3
number of strokes per cartridge cca 1560
operating pressure 70 bar
control PLC
lubricant grease up to NLGI class 2, solid particless possible
operating temperature - 10o C … + 60o C
operating voltage 24V DC (via cable)
connector M12x1; 4-pole
mounting position arbitrary
pressure monitoring integrated, electronic
level monitoring integrated, reedcontact
protection class IP54
number of outlets max. 4, angled, turnable
outlet for tube 6
number of pump bodies 1 or 2
number of lubrication points max. 40
tube length max. 2m in front of the distributor
  max. 6m behind of the distributor
  max. 10m without distributor

ORDER CODES

FlexxPump 211 DLS (1 pump, 1 outlet) 235-211-210
FlexxPump 212 DLS (1 pump, 2 outlets) 235-212-210
FlexxPump 222 DLS (2 pumps, 2 outlets) 235-222-210
FlexxPump 223 DLS (2 pumps, 3 outlets) 235-223-210
FlexxPump 224 DLS (2 pumps, 4 outlets) 235-224-210
cartridge for FP250; 250 cm³; F03 grease 000-103-103
Cable M12x1; straight; 4-pole; open end; 5m 134-002-003
Cable M12x1; straight; 4-pole; open end; 10m 134-002-007
Tube 6x4; filled with grease F03 134-003-003